Thermal runaway in nickel-cadmium batteries with sintered and extruded electrodes
It is shown by experiments that probability of thermal runway in nickel-cadmium batteries with sintered oxide-nickel electrodes is higher, than in the batteries with extruded and pasted electrodes. Besides, it is shown that the probability of thermal runaway decreases with decrease of battery capacitance.
1. Guo Y. Thermal Runaway. Encyclopedia of Electrochemical Power Sources. Elsevier, 2009.
2. Коровин Н. В., Скундин А. М. Химические источники тока: справочник. М.: Изд-во Моск. энерг. ин-та, 2003.
3. Галушкина Н. Н., Галушкин Н. Е., Галушкин Д. Н. // Электрохим. энергетика. 2005. Т. 5, № 1. С. 40–42.
4. Галушкина Н. Н., Галушкин Д. Н. // Электрохим. энергетика. 2005. Т. 5, № 3. С. 206–208.
5. Галушкин Д. Н., Галушкина Н. Н. // Электрохим. энергетика. 2006. Т. 6, № 2. С. 76–78.
6. Галушкин Д. Н. // Электрохим. энергетика. 2007. Т. 7, № 3. С. 128–131.
7. Галушкин Д. Н., Язвинская Н. Н. // Электрохим. энергетика. 2008. Т. 8, № 4. С. 241–246.