Tests of the sealed nickel-cadmium storage batteries for capacity safety during long-term storage after charging with direct and asymmetric currents

Comparative results of the tests of the sealed nickel-cadmium batteries for capacity safety during long-term storage after charging with direct and asymmetric currents are represented. Charging with asymmetric current was carried out in an accelerated manner at average value of the charging current equal to 0.8Crated. Charging with direct current was carried out at average value of the charging current equal to 0. lCrated in accordance with Technical Conditions.