Portable sealed lead accumulators and batteries
Autors:
Barsukova M. M., JSC NIAI Istochnik
Kolikova G. A., JSC NIAI Istochnik
Abstract:
The research results of the sealed lead-acid (SLA) batteries of domestic and foreign production are considered. The effect of temperature on the SLA batteries operational performances was investigated. The relationship between the open-curcuit voltage (OCV) and the SLA battery stage-of-charge as well as the relationship between the open-curcuit voltage (OCV) and the battery impedance were determined. The high accuracy of the stage-of-charge diagnosis method based on the battery OCV measuring was proven.
Reference:
- Коликова Г. А., Барсукова М. М. // Электротехника. 2002. № 10. С. 57.
- ГОСТ Р МЭК 61056-1-99. Портативные свинцово-кислотные аккумуляторы и батареи (закрытого типа). Ч. 1. Общие требования, функциональные характеристики. Методы испытаний.