Current leads corrosion and the problem of diagnostics of fluorocarbon-lithium cells
Corrosion behavior of niobium current leads of fluorocarbon-lithium cells are studied. Polarization measurements at plain niobium leads and at such leads in a contact with fluorocarbon cathode in an electrolyte of fluorocarbon-lithium cell were carried out. Besides, behavior of niobium lead directly in a feedthrough of real cells was studied. The contact of niobium with fluorocarbon cathode is shown to result in toughening of corrosion conditions and in possible niobium depassivation. Long-term cells storage at elevated temperature was shown to result in complete corrosion dissolution of niobium leads. Certain correlation between cell's OCV and corrosion intensity was obtained.
- Pat. 5306581 US. C03C 8/24 (20060101). Battery with weldable feedthrough.
- Pat. 5811206 US. H01M 2/06 (20060101). Feedthrough pin insulator, assembly and method for electrochemical cell.
- Пат. 33 000 И1 РФ. МПК7 A61F 2/70 Источник тока для имплантируемых медицинских приборов.
- Фатеев С. А., Рынсков Е.В, Ясюкевич Д. О. // Вестн. РАЕН. 2007. Т. 7, № 3. С. 33–36.