Influence of Asymmetric Current Parameters on Nickel-Cadmium Accumulators Formation Process Time
Comparison of asymmetric current parameters influence on nickel-cadmium accumulators forming time is performed. According to the results of capacity forming of NKM-22 accumulators with thin pressed cadmium and metal-ceramic electrodes, the perspective of application of asymmetric current with parameters chosen during experiments and used in this paper is established. Waveforms giving the biggest increase of capacity comply with the most economical parameters defined om models during experiments. In particular, application of asymmetric current with such parameters for NKM-22 accumulators forming gave 11% increase of discharge capacity compared with direct current forming.
1. Матекин С. С. Формирование и восстановление ёмкости никель-кадмиевых аккумуляторов и батарей: дис. ... канд. техн. наук. Новочеркасск, 2007. 158 с.
2. Сметанкин Г. П., Матекин С. С., Бурдюгое А. С. // Электрохим. энергетика. 2009. Т. 9, № 1. С. 40–43.